<?xml version="1.0" encoding="UTF-8"?>
<!DOCTYPE article PUBLIC "-//NLM//DTD JATS (Z39.96) Journal Publishing DTD v1.3 20210610//EN" "JATS-journalpublishing1-3.dtd">
<article article-type="research-article" dtd-version="1.3" xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xml:lang="ru"><front><journal-meta><journal-id journal-id-type="publisher-id">medbio</journal-id><journal-title-group><journal-title xml:lang="ru">Медико-биологические проблемы жизнедеятельности</journal-title><trans-title-group xml:lang="en"><trans-title>Medical and Biological Problems of Life Activity</trans-title></trans-title-group></journal-title-group><issn pub-type="ppub">2074-2088</issn><publisher><publisher-name>Республиканский научно-практический центр радиационной медицины и экологии человека</publisher-name></publisher></journal-meta><article-meta><article-id pub-id-type="doi">10.58708/2074-2088.2026-1(37)-61-68</article-id><article-id custom-type="elpub" pub-id-type="custom">medbio-504</article-id><article-categories><subj-group subj-group-type="heading"><subject>Research Article</subject></subj-group><subj-group subj-group-type="section-heading" xml:lang="ru"><subject>КЛИНИЧЕСКАЯ МЕДИЦИНА</subject></subj-group><subj-group subj-group-type="section-heading" xml:lang="en"><subject>CLINICAL MEDICINE</subject></subj-group></article-categories><title-group><article-title>Дистанция «диск зрительного нерва — макула» как независимый предиктор рефракционных исходов после факоэмульсификации с имплантацией ИОЛ</article-title><trans-title-group xml:lang="en"><trans-title>The «optic disc — macula» distance as an independent predictor of refractive outcomes after phacoemulsification with IOL implantation</trans-title></trans-title-group></title-group><contrib-group><contrib contrib-type="author" corresp="yes"><contrib-id contrib-id-type="orcid">https://orcid.org/0009-0002-9013-6616</contrib-id><name-alternatives><name name-style="eastern" xml:lang="ru"><surname>Гридюшко</surname><given-names>С. М.</given-names></name><name name-style="western" xml:lang="en"><surname>Gridjushko</surname><given-names>S. M.</given-names></name></name-alternatives><bio xml:lang="ru"><p>г. Гомель</p></bio><email xlink:type="simple">Grd.sergey8@gmail.com</email><xref ref-type="aff" rid="aff-1"/></contrib><contrib contrib-type="author" corresp="yes"><contrib-id contrib-id-type="orcid">https://orcid.org/0000-0002-5852-2616</contrib-id><name-alternatives><name name-style="eastern" xml:lang="ru"><surname>Красильникова</surname><given-names>В. Л.</given-names></name><name name-style="western" xml:lang="en"><surname>Krasilnikova</surname><given-names>V. L.</given-names></name></name-alternatives><bio xml:lang="ru"><p>г. Минск</p></bio><email xlink:type="simple">krasilnikova_vil@mail.ru</email><xref ref-type="aff" rid="aff-2"/></contrib><contrib contrib-type="author" corresp="yes"><contrib-id contrib-id-type="orcid">https://orcid.org/0009-0004-6554-3230</contrib-id><name-alternatives><name name-style="eastern" xml:lang="ru"><surname>Дудич</surname><given-names>О. Н.</given-names></name><name name-style="western" xml:lang="en"><surname>Dudich</surname><given-names>O. N.</given-names></name></name-alternatives><bio xml:lang="ru"><p>г. Минск</p></bio><email xlink:type="simple">oksana_s20@mail.ru</email><xref ref-type="aff" rid="aff-2"/></contrib><contrib contrib-type="author" corresp="yes"><contrib-id contrib-id-type="orcid">https://orcid.org/0000-0002-6180-1819</contrib-id><name-alternatives><name name-style="eastern" xml:lang="ru"><surname>Прудник</surname><given-names>А. М.</given-names></name><name name-style="western" xml:lang="en"><surname>Prudnik</surname><given-names>A. M.</given-names></name></name-alternatives><bio xml:lang="ru"><p>г. Минск</p></bio><email xlink:type="simple">aleksander.prudnil@bsuir.by</email><xref ref-type="aff" rid="aff-3"/></contrib></contrib-group><aff xml:lang="ru" id="aff-1"><institution>УЗ "Гомельская областная специализированная клиническая больница"</institution><country>Belarus</country></aff><aff xml:lang="ru" id="aff-2"><institution>УО «Белорусский государственный медицинский университет»</institution><country>Belarus</country></aff><aff xml:lang="ru" id="aff-3"><institution>УО «Белорусский государственный университет информатики&#13;
и радиоэлектроники»</institution><country>Belarus</country></aff><pub-date pub-type="collection"><year>2026</year></pub-date><pub-date pub-type="epub"><day>04</day><month>06</month><year>2026</year></pub-date><volume>0</volume><issue>1</issue><fpage>61</fpage><lpage>68</lpage><permissions><copyright-statement>Copyright &amp;#x00A9; Гридюшко С.М., Красильникова В.Л., Дудич О.Н., Прудник А.М., 2026</copyright-statement><copyright-year>2026</copyright-year><copyright-holder xml:lang="ru">Гридюшко С.М., Красильникова В.Л., Дудич О.Н., Прудник А.М.</copyright-holder><copyright-holder xml:lang="en">Gridjushko S.M., Krasilnikova V.L., Dudich O.N., Prudnik A.M.</copyright-holder><license xml:lang="ru" license-type="creative-commons-attribution" xlink:href="https://creativecommons.org/licenses/by/4.0/" xlink:type="simple"><license-p>Данная работа распространяется под лицензией Creative Commons Attribution 4.0.</license-p></license><license xml:lang="en" license-type="creative-commons-attribution" xlink:href="https://creativecommons.org/licenses/by/4.0/" xlink:type="simple"><license-p>This work is licensed under a Creative Commons Attribution 4.0 License.</license-p></license></permissions><self-uri xlink:href="https://medbio.ejournal.by/jour/article/view/504">https://medbio.ejournal.by/jour/article/view/504</self-uri><abstract><p>Современные методы расчёта интраокулярных линз не всегда позволяют достичь идеальной рефракции, что связано с влиянием дополнительных анатомических факторов. В данном ретроспективном когортном исследовании оценивалось влияние дистанции «диск зрительного нерва – макула», измеренной методом оптической когерентной томографии, на рефракционные исходы после факоэмульсификации с имплантацией ИОЛ у пациентов с катарактой. Измерение дистанции проводилось на ОКТ-изображениях, после чего были выполнены корреляционный, регрессионный и ROC-анализы с последующей валидацией на контрольной выборке. Установлено, что изучаемый анатомический параметр является независимым предиктором рефракционной ошибки. Определено пороговое значение, позволяющее с высокой чувствительностью прогнозировать риск клинически значимого отклонения от целевой рефракции. Характер влияния дистанции различается в зависимости от исходной рефракции: в гиперметропических глазах с короткой осью выявлена выраженная обратная корреляция с остаточной гиперметропией, тогда как при миопии эффект опосредован аксиальной длиной глаза. Полученные данные обосновывают целесообразность предоперационного измерения дистанции «диск зрительного нерва – макула» для персонализации расчёта ИОЛ, особенно у пациентов с гиперметропией, что позволит минимизировать риск непредвиденных рефракционных ошибок и повысить удовлетворённость пациентов.</p></abstract><trans-abstract xml:lang="en"><p>Modern intraocular lens calculation methods do not always achieve ideal refraction due to the influence of additional anatomical factors. This retrospective cohort study evaluated the effect of the optic disc–macula distance, measured by optical coherence tomography, on refractive outcomes after phacoemulsification with IOL implantation in cataract patients. The distance was measured on OCT images, followed by correlation, regression, and ROC analyses with subsequent validation on a control sample. It was established that the studied anatomical parameter is an independent predictor of refractive error. A threshold value was determined that allows for high-sensitivity prediction of the risk of a clinically significant deviation from the target refraction. The nature of the distance’s influence varies depending on the baseline refraction: in hyperopic eyes with a short axis, a pronounced inverse correlation with residual hyperopia was revealed, whereas in myopia, the effect is mediated by the axial length of the eye. These findings substantiate the feasibility of preoperative measurement of the optic disc–macula distance for personalized IOL calculation, especially in patients with hyperopia, which will minimize the risk of unexpected refractive errors and increase patient’s satisfaction.</p></trans-abstract><kwd-group xml:lang="ru"><kwd>афакия</kwd><kwd>катаракта</kwd><kwd>дистанция «диск — макула»</kwd><kwd>оптическая когерентная томография</kwd><kwd>рефракционная ошибка</kwd><kwd>интраокулярная линза</kwd><kwd>персонализированная хирургия</kwd></kwd-group><kwd-group xml:lang="en"><kwd>aphakia</kwd><kwd>ataract</kwd><kwd>disc–macula distance</kwd><kwd>optical coherence tomography</kwd><kwd>refractive error</kwd><kwd>intraocular lens</kwd><kwd>personalized surgery</kwd></kwd-group></article-meta></front><back><ref-list><title>References</title><ref id="cit1"><label>1</label><citation-alternatives><mixed-citation xml:lang="ru">Петров, С.Ю. Катаракта: современный взгляд на консервативные подходы к лечению / С.Ю. Петров, И.В. Козлова, Р.П. Полева // Русский медицинский журнал. Клиническая офтальмология. – 2019. – Т. 19, №4. – С. 206–210. DOI: 10.32364/2311-7729-2019-19-4-206-210</mixed-citation><mixed-citation xml:lang="en">Petrov SYu, Kozlova IV, Poleva RP. Cataract: a modern view of conservative treatment approaches. Russian Medical Journal. Clinical Ophthalmology. 2019;19(4):206-210. DOI: 10.32364/2311-7729-2019-19-4-206-210. [In Russian].</mixed-citation></citation-alternatives></ref><ref id="cit2"><label>2</label><citation-alternatives><mixed-citation xml:lang="ru">Оптическая биометрия глаза: принцип и диагностические возможности метода / Т.Н. Киселева, О.Г. Оганесян, Л.И. Романова [и др.] // Российская педиатрическая офтальмология. – 2017. – Т. 12, №1. – С. 35–42. DOI: 10.18821/1993-1859-2017-12-1-35-42</mixed-citation><mixed-citation xml:lang="en">Kiseleva TN, Oganesyan OG, Romanova LI, et al. Optical biometry of the eye: principle and diagnostic capabilities. Russian Pediatric Ophthalmology. 2017;12(1):35-42. DOI: 10.18821/1993-1859-2017-12-1-35-42. [In Russian].</mixed-citation></citation-alternatives></ref><ref id="cit3"><label>3</label><citation-alternatives><mixed-citation xml:lang="ru">Куликов, А.Н. Сравнение результатов биометрии глаза при использовании различных приборов / А.Н. Куликов, Е.В. Кокарева, Н.А. Котова // Тихоокеанский медицинский журнал. – 2017. – № 2. – С. 53–55. DOI: 10.17238/PmJ1609-1175.2017.2.53-55</mixed-citation><mixed-citation xml:lang="en">Kulikov AN, Kokareva EV, Kotova NA. Comparison of eye biometry results using different devices. Pacific Medical Journal. 2017;(2):53-55. DOI: 10.17238/PmJ1609-1175.2017.2.53-55. [In Russian].</mixed-citation></citation-alternatives></ref><ref id="cit4"><label>4</label><citation-alternatives><mixed-citation xml:lang="ru">Маковкин, Е.М. Клиническое значение величины отклонения зрительной оси глазного яблока от его анатомической оси / Е.М. Маковкин // Вестник Волгоградского государственного медицинского университета. – 2008. – Вып. 1 (25). – С. 77–79.</mixed-citation><mixed-citation xml:lang="en">Makovkin EM. Clinical significance of deviation of the visual axis of the eyeball from its anatomical axis. Bulletin of Volgograd State Medical University. 2008;1(25):77-79. [In Russian].</mixed-citation></citation-alternatives></ref><ref id="cit5"><label>5</label><citation-alternatives><mixed-citation xml:lang="ru">Melles, R.B. Update on intraocular lens calculation formulas / R.B. Melles, J.X. Kane, T. Olsen, W.J. Chang // Ophthalmology. – 2019. – Vol. 126, №9. – P. 1334–1335. DOI: 10.1016/j.ophtha.2019.04.011</mixed-citation><mixed-citation xml:lang="en">Melles RB, Kane JX, Olsen T, Chang WJ. Update on intraocular lens calculation formulas. Ophthalmology. 2019;126(9):1334-1335. DOI: 10.1016/j.ophtha.2019.04.011.</mixed-citation></citation-alternatives></ref><ref id="cit6"><label>6</label><citation-alternatives><mixed-citation xml:lang="ru">Tabernero, J. Impact of foveal location on postoperative refraction after cataract surgery / J. Tabernero, P. Artal // Journal of Cataract &amp; Refractive Surgery. – 2020. – Vol. 46, №5. – P. 732–736. DOI: 10.1097/j.jcrs.0000000000000123</mixed-citation><mixed-citation xml:lang="en">Tabernero J, Artal P. Impact of foveal location on postoperative refraction after cataract surgery. J Cataract Refract Surg. 2020;46(5):732-736. DOI: 10.1097/j.jcrs.0000000000000123.</mixed-citation></citation-alternatives></ref><ref id="cit7"><label>7</label><citation-alternatives><mixed-citation xml:lang="ru">Prediction of postoperative intraocular lens tilt using swept-source optical coherence tomography / N. Hirnschall, T. Buehren, F. Bajramovic [et al.] // Journal of Cataract &amp; Refractive Surgery. – 2017. – Vol. 43, №6. – P. 732–736. DOI: 10.1016/j.jcrs.2017.01.026</mixed-citation><mixed-citation xml:lang="en">Hirnschall N, Buehren T, Bajramovic F, et al. Prediction of postoperative intraocular lens tilt using swept-source optical coherence tomography. J Cataract Refract Surg. 2017;43(6):732-736. DOI: 10.1016/j.jcrs.2017.01.026.</mixed-citation></citation-alternatives></ref><ref id="cit8"><label>8</label><citation-alternatives><mixed-citation xml:lang="ru">Positions of ocular geometrical and visual axes in Brazilian, Chinese and Italian populations / A. Abass, R. Vinciguerra, B.T. Lopes [et al.] // Current Eye Research. – 2018. – Vol. 43, №11. – P. 1404–1414. DOI: 10.1080/02713683.2018.1500609</mixed-citation><mixed-citation xml:lang="en">Abass A, Vinciguerra R, Lopes BT, et al. Positions of ocular geometrical and visual axes in Brazilian, Chinese and Italian populations. Curr Eye Res. 2018;43(11):1404-1414. DOI: 10.1080/02713683.2018.1500609.</mixed-citation></citation-alternatives></ref><ref id="cit9"><label>9</label><citation-alternatives><mixed-citation xml:lang="ru">Liu, Y. Association between foveal location and refractive error after cataract surgery in high myopia / Y. Liu, L. Wang, Z. Yang // Eye. – 2022. – Vol. 36, №8. – P. 1621–1627. DOI: 10.1038/s41433-021-01789-5</mixed-citation><mixed-citation xml:lang="en">Liu Y, Wang L, Yang Z. Association between foveal location and refractive error after cataract surgery in high myopia. Eye (Lond). 2022;36(8):1621-1627. DOI: 10.1038/s41433-021-01789-5.</mixed-citation></citation-alternatives></ref><ref id="cit10"><label>10</label><citation-alternatives><mixed-citation xml:lang="ru">Song, J.S. Fovea-disc distance as a predictor of postoperative refraction in axial myopia / J.S. Song, D.H. Kim, J.Y. Lee // Korean Journal of Ophthalmology. – 2023. – Vol. 37, №2. – P. 98–105. DOI: 10.3341/kjo.2022.0156</mixed-citation><mixed-citation xml:lang="en">Song JS, Kim DH, Lee JY. Fovea-disc distance as a predictor of postoperative refraction in axial myopia. Korean J Ophthalmol. 2023;37(2):98-105. DOI: 10.3341/kjo.2022.0156.</mixed-citation></citation-alternatives></ref><ref id="cit11"><label>11</label><citation-alternatives><mixed-citation xml:lang="ru">Olsen, T. Calculation of intraocular lens power: a review / T. Olsen // Acta Ophthalmologica Scandinavica. – 2007. – Vol. 85, №5. – P. 472–485. DOI: 10.1111/j.1600-0420.2007.00879.x</mixed-citation><mixed-citation xml:lang="en">Olsen T. Calculation of intraocular lens power: a review. Acta Ophthalmol Scand. 2007;85(5):472-485. DOI: 10.1111/j.1600-0420.2007.00879.x.</mixed-citation></citation-alternatives></ref><ref id="cit12"><label>12</label><citation-alternatives><mixed-citation xml:lang="ru">Lundström, M. Catquest-9SF patient outcomes questionnaire: nine-item short-form Raschscaled revision of the Catquest questionnaire / M. Lundström, K. Pesudovs // Journal of Cataract &amp; Refractive Surgery. – 2009. – Vol. 35, №3. – P. 504–513. DOI: 10.1016/j.jcrs.2008.11.038</mixed-citation><mixed-citation xml:lang="en">Lundström M, Pesudovs K. Catquest-9SF patient outcomes questionnaire: nine-item short-form Rasch-scaled revision of the Catquest questionnaire. J Cataract Refract Surg. 2009;35(3):504-513. DOI: 10.1016/j.jcrs.2008.11.038.</mixed-citation></citation-alternatives></ref><ref id="cit13"><label>13</label><citation-alternatives><mixed-citation xml:lang="ru">Hoffer, K.J. Update on intraocular lens power calculation study protocols: the better way to design and report clinical trials / K.J. Hoffer, W. Haigis, T. Olsen // Ophthalmology. – 2021. – Vol. 128, №11. – P. e115–e120. DOI: 10.1016/j.ophtha.2020.07.005</mixed-citation><mixed-citation xml:lang="en">Hoffer KJ, Haigis W, Olsen T. Update on intraocular lens power calculation study protocols: the better way to design and report clinical trials. Ophthalmology. 2021;128(11):e115-e120. DOI: 10.1016/j.ophtha.2020.07.005.</mixed-citation></citation-alternatives></ref><ref id="cit14"><label>14</label><citation-alternatives><mixed-citation xml:lang="ru">Intraocular lens power formula accuracy: comparison of 7 formulas / J.X. Kane, A. Van Heerden, A. Atik [et al.] // Journal of Cataract &amp; Refractive Surgery. – 2016. – Vol. 42, №10. – P. 1490–1500. DOI: 10.1016/j.jcrs.2016.07.021</mixed-citation><mixed-citation xml:lang="en">Kane JX, Van Heerden A, Atik A, et al. Intraocular lens power formula accuracy: comparison of 7 formulas. J Cataract Refract Surg. 2016;42(10):1490-1500. DOI: 10.1016/j.jcrs.2016.07.021.</mixed-citation></citation-alternatives></ref><ref id="cit15"><label>15</label><citation-alternatives><mixed-citation xml:lang="ru">Разработка шкалы для определения удовлетворенности пациента результатом хирургического лечения и выбором интраокулярной линзы в зависимости от рефракции цели / В.Л. Красильникова, О.Н. Дудич, С.М. Гридюшко [и др.] // Вестник Витебского государственного медицинского университета. – 2025. – Т. 24, №1. – С. 89–100. DOI: 10.22263/2312-4156.2025.1.89</mixed-citation><mixed-citation xml:lang="en">Krasilnikova VL, Dudich ON, Gridyushko SM, et al. Development of a scale to determine patient satisfaction with surgical outcome and intraocular lens choice depending on refractive target. Vestnik Vitebsk State Med Univ. 2025;24(1):89-100. DOI: 10.22263/2312-4156.2025.1.89. [In Russian].</mixed-citation></citation-alternatives></ref></ref-list><fn-group><fn fn-type="conflict"><p>The authors declare that there are no conflicts of interest present.</p></fn></fn-group></back></article>
